Warranty: | 3years |
---|---|
Nominal Capacity: | 100ah |
Cycle Life: | 4000 |
Oed: | Welcome |
Design: | Spport |
Connection Mode: | Series and Parallel |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
NO | Description | |
1 | Height(H)/mm | 720 |
2 | Width(W)/mm | 480 |
3 | Thickness(T)/mm | 160 |
4 | Net Weight /Kg | 58 |
No. | Description | Remark |
1 | Switch | ON/OFF |
2 | LED | ON/OFF |
3 | LED | RUN |
4 | LED | ALM |
5 | LED | SOC |
6 | Anderson Terminal | Positive port/Negative port |
7 | RS485 | RS485 |
8 | RS232 | RS232 |
9 | CAN | CAN |
10 | Dry Contact | Dry Contact |
11 | ADD | ADD |
12 | Reset | Reset |
13 | Wall Mount | Wall mount bracket |
14 | Handle | Handle |
NO | Projects | Specification | Remark |
Cell Unit Parameter | |||
1 | Battery types and materials | LiFePO4 | / |
2 | Rated voltage/capacity | 3.2V/100Ah | / |
3 | Single battery voltage range | 2.0V~3.7V | / |
4 | Single battery weight | 1.94Kg | / |
5 | The battery internal resistance | ≤ 0.5mΩ | / |
6 | Battery size | 52.32*148.4*119mm(T*W*H) | / |
Battery Parameter | |||
1 | Rated voltage | 51.2V | / |
2 | Rated capacity | 100Ah | / |
3 | Battery pack voltage range | 43.2~59.2V | / |
4 | Total Power(kWh) | 5120Wh | / |
5 | Combination | 1P16S | / |
6 |
Insulation resistance test value(Ω) |
≤50mΩ |
/ |
7 | Operating temperature | Charging 0 ~ 45ºC; Discharging -10 ~ 50ºC | / |
8 | Standard charging current | 40A(0.4C) | / |
9 | Quick charging current | 50A(0.5C) | / |
10 | Standard discharge current | 80A(0.8C) | / |
11 | Maximum continuous discharge current | 100A(1C) | / |
12 | Gross weight | 65Kg | / |
13 | Ambient relative humidity | 25-85%RH | / |
14 | Battery size | 160*480*720mm(±2mm) (T*W*H) | / |
15 |
Open circuit voltage |
Open circuit voltage measured within 24 hours after standard charge | ≥51V |
16 |
Capacity retention |
Fully charging, store them at (20±5)ºC for 28 days, then discharge to 40V @0.2C. | ≥300min Discharging time≥300min |
17 |
Cycle Life @25ºC |
Discharge to 40V @0.2C, then Charge the battery @0.2C to reach 58V. Then charge the battery at constant58.4V voltage until the charging current decreasing to 0.02C. Rest for 10 min. discharge to 40V@ 0.2C and rest for 10 min. Continue the charge/discharge cycles until discharge capacity lower than 80% of rated capacity. |
Cycles life ≥4000 |
18 |
storage |
Charge the battery to 40%~65% of its rated capacity using standard charging mode, then keep it in a 20ºC±5ºC, humidity 45%~85% room for 12 months, fully charge and discharge it @0.2C until voltage is down. (The testing sample should be within 3 months dated from the production date) |
≥300min Discharge time≥360min |